4/09/2013

Wideband Sense & Heater Control ADC muxing 74HC4052



 The dual 4 to 1 line mux U4 (74HC4052) allows two groups of four signals to be sensed by the microcontroller's two ADC input lines ADC0 and ADC1.

Wideband signals Vsx5, Ih, Vsx1, IpSense, DACV & Cal (VGND) voltages are sensed as well as H- via filtering provided by R112 and C103. also shown here is the H+ sense signal but it is not selected by the mux, but rather passed directly to the microcontroller via filter components R111 and C102.

Analogue user channel 1 USR1 (see Y5 connector input below) is also sensed by this mux.

No comments:

Post a Comment